With the carburetor and float chambers removed, hold the assembly so that the surface of the float chamber is approximately 30°from vertical. Use a float level gauge (tool 07401-0010000 or equivalent) for measuring the float level with the float tip in light contact with the float valve. The correct measurement is 15-17 mm. Adjust floats as needed.